Getting out of the way: my robotics crash course

(thisismypersonalblog.com)

20 points | by systemerror 2 days ago

2 comments

  • pj_mukh 1 hour ago
    Shoutout to people who don't overthink blog setups. "thisismypersonalblog.com" AND GO. It'll do the job.

    On a technical note, your setup is not far from where professional setups are headed [1]. Astra is really doing an end-run around (for now) research Robotics setups.

    [1]: https://x.com/ihorbeaver/status/2104646736652447854?s=20

  • jvanderbot 1 hour ago
    First law of calibration: Make sure you do an error analysis.

    Finding the table surface is pretty useless using a top-down view, even with April tags, because the range error to an april tag is much more than the bearing (pixel) error to the april tag. You basically have trouble observing the thing you're trying to measure.

    If you do this again, ask your agent to conduct this analysis and make sure your desired calibration variables are observable with small error. A second camera from a 45deg angle or even on the table would go a lot further, but then of course other things become unobservable.

    Nice workaround using a proxy for force sensing to get touch info, however. And neat project overall!